<Back Overview
- Model: SF4 / SF4F / SF5 / SF6 / SF7 / SF8 / SF9 / SK1 / SK2
Thermowells are applied to protect a thermometer stem against difficult chemical and mechanical process conditions. Furthermore it is far easier to dismount a thermometer e.g. for repair or other reasons, when a thermowell stays at the measuring point.
Our thermowell models SF4 to SF9 correspond to the thermowell forms 4 to 9 of DIN 43 772 that was enacted in March 2000. Our models SK1 and SK2 with clamp fitting are designed additionally to DIN 43772.
These new thermowell models replace our former thermowells acc. to DIN 16179 that were parts of our stem types A8 to A13. Nevertheless, the old stem types are still available upon request.
Or weld-in process connection solid drilled, suitable for
our thermometer stem types A4 (turnable male connection) and
A4.1 (rigid male connection).
With DIN EN, DIN, or ASME flange, thermowell solid drilled, suitable for our thermometer stem types A4 (turnable male connection) and A4.1 (rigid male connection).
½" BSP or ¾" BSP male process connection,
thermowell fabricated, suitable for our thermometer stem types
A4 (turnable male connection) and A4.1 (rigid male connection).
½" BSP or ¾" BSP male process connection, thermowell solid drilled, suitable for our thermometer stem types A4 (turnable male connection) and A4.1 (rigid male connection).
½" NPT or ¾" NPT male process connection, thermowell solid drilled, suitable for our thermometer stem types A4 (turnable male connection) and A4.1 (rigid male connection).